Honeywell Economizer Controller Manual: A Comprehensive Guide
Honeywell delivers leading economizer controls, offering various models like W7220 and W7215A, compatible with JADE for advanced setup and energy savings.
Honeywell economizer controllers represent a cornerstone of modern HVAC system optimization, providing precise and efficient free cooling strategies. These systems, including models like the W7220 and W7215A, integrate seamlessly with Honeywell’s JADE advanced setup for comprehensive control.
Designed for commercial applications, these controllers manage outdoor and return-air dampers, maximizing energy savings while adhering to ventilation codes. Understanding their functionality is crucial for installers, technicians, and building managers seeking to enhance system performance and reduce operational costs. This guide provides a detailed overview.

Understanding Economizer Basics
Economizers leverage cool outdoor air for free cooling, reducing reliance on mechanical refrigeration. Honeywell economizer controllers intelligently modulate dampers to blend outdoor and return air, optimizing temperature and humidity. This process significantly lowers energy consumption and operational expenses.
The core principle involves comparing outdoor air conditions to return air, activating the economizer cycle when advantageous. Proper setup, utilizing sensors for mixed and outdoor air temperatures, is vital for efficient operation and adherence to ventilation standards.
What is an Economizer and How Does it Work?
An economizer is a system that utilizes cool outdoor air to reduce or eliminate the need for mechanical cooling. Honeywell economizer controllers manage dampers, proportionally mixing outdoor air with return air based on temperature and humidity. When outdoor conditions are favorable, the controller minimizes compressor runtime.

This free cooling method lowers energy costs and enhances indoor air quality. The W7220 module, for example, can be configured for various applications, optimizing performance in commercial HVAC systems. Accurate sensor readings are crucial for effective control.
Benefits of Using an Economizer System
Implementing a Honeywell economizer system yields significant advantages. Primarily, it drastically reduces energy consumption by leveraging free cooling when outdoor air is suitable, lowering operational costs. These systems also improve Indoor Air Quality (IAQ) through increased ventilation.
Honeywell controls ensure compliance with modern ventilation codes. Utilizing economizers extends the lifespan of HVAC equipment by reducing compressor workload. Models like the W7220 offer precise control, maximizing efficiency and comfort within commercial buildings.
Honeywell Economizer Controller Models
Honeywell offers a diverse range of economizer controllers tailored for various HVAC applications. Key models include the W7220 Economizer Module, known for its full modulating capabilities and compatibility with Bard units. The W7215A is frequently paired with T775 controllers and Series 72 actuators.
Furthermore, Honeywell provides Logic Modules – W7212A, W7213A, and W7214A – enhancing system flexibility. These models support diverse configurations, ensuring optimal performance and energy efficiency in commercial buildings, offering robust control solutions.
W7220 Economizer Module: Features and Applications
The Honeywell W7220 Economizer Module provides full modulating control, ideal for Bard W30AB, W30HB, W36AB, and W36HB models. It expertly proportions outdoor and return-air dampers, maximizing free cooling in commercial HVAC systems. Configurable for four distinct applications, the W7220 enhances energy efficiency.
This module seamlessly integrates with JADE, enabling advanced setup and precise temperature regulation. Its robust design ensures reliable operation, contributing to significant cost savings and improved indoor air quality. It’s a cornerstone of modern economizer systems.
W7215A Economizer Controller: Compatibility and Usage
The Honeywell W7215A Economizer Controller is designed for use with the T775 Controller and Honeywell Series 72 Actuator. Crucially, actuator model selection depends on the specific logic module model utilized within the system. This controller facilitates effective outdoor air control, optimizing ventilation and reducing energy consumption.
Proper installation requires careful attention to power requirements and actuator compatibility. The W7215A contributes to meeting modern ventilation codes, offering a reliable solution for commercial HVAC applications. It’s a vital component for efficient climate management.
Logic Modules for Honeywell Economizer Systems (W7212A, W7213A, W7214A)
Honeywell offers W7212A, W7213A, and W7214A logic modules designed for compatibility with Honeywell 2-position, floating, and 3-position actuators. These modules are versatile, functioning with various economizer systems. They provide essential control logic for damper positioning, enabling efficient free cooling strategies.
These modules are integral to optimizing HVAC performance, allowing for customized configurations based on specific application needs. They work seamlessly with other Honeywell components, ensuring a cohesive and reliable control system.
Installation and Wiring
Honeywell economizer installation requires careful attention to wiring diagrams specific to each model, such as the W7220. Proper mounting ensures stable operation, considering physical space and accessibility for maintenance.
Wiring involves connecting sensors, actuators, and the controller itself, adhering to electrical safety guidelines. Accurate wiring is crucial for correct functionality and preventing system failures. Refer to detailed documentation for specific wiring configurations and component placement for optimal performance.
Wiring Diagrams for Common Honeywell Economizer Models
Honeywell provides detailed wiring diagrams for popular economizer models like the W7220, W7215A, and those utilizing logic modules (W7212A, W7213A, W7214A). These diagrams illustrate connections for power, sensors (mixed air, outdoor air), and actuators.

Understanding these diagrams is vital for correct installation. They specify wire gauges, terminal designations, and proper grounding procedures. Always consult the specific diagram corresponding to your installed model to ensure accurate and safe wiring practices, avoiding potential control issues;
Mounting and Physical Installation Considerations
Honeywell economizer controllers require careful mounting to ensure reliable operation. Select a location protected from extreme temperatures, humidity, and physical damage. Securely fasten the controller using appropriate hardware, avoiding vibration sources.
Proper sensor placement is crucial for accurate readings; position mixed air and outdoor air sensors away from direct sunlight or exhaust streams. Ensure adequate wiring access and follow all local electrical codes during installation. Consider airflow patterns when mounting to prevent inaccurate temperature measurements.
Configuration and Programming
Honeywell economizer controllers offer flexible configuration options via the JADE Advanced Setup. This interface allows precise adjustment of mixed air and outdoor air temperature sensors, optimizing free cooling performance.
Key parameters include economizer control settings, deadband adjustments, and minimum/maximum airflow limits. Proper programming ensures efficient operation and adherence to ventilation codes. Careful consideration of building characteristics and occupancy schedules is vital for maximizing energy savings and maintaining occupant comfort.
Using the JADE Advanced Setup for Honeywell Economizers
JADE provides a user-friendly interface for configuring Honeywell economizers. Accessing the setup allows for detailed parameter adjustments, including sensor calibration and control logic settings.

Navigating the menus enables technicians to define economizer modes, set temperature thresholds, and customize damper control strategies. The software facilitates efficient troubleshooting and diagnostics, displaying real-time data and historical trends. Ryan Hoger’s series highlights the JADE setup’s capabilities for optimizing performance.
Configuring Mixed Air and Outdoor Air Temperature Sensors

Honeywell economizers rely on accurate temperature readings from mixed air (MAT) and outdoor air (OAT) sensors. Proper configuration within the JADE setup is crucial for optimal performance.
The system requires defining the sensor model number for correct calibration. Accurate sensor data enables precise control of dampers, maximizing free cooling opportunities. Ensuring correct wiring and sensor placement are vital for reliable operation, contributing to energy efficiency and code compliance.

Setting Up Economizer Control Parameters
Honeywell’s JADE Advanced setup allows fine-tuning of economizer control. Key parameters include the economizer changeover temperature, defining when free cooling initiates. Adjusting the minimum outdoor air temperature ensures sufficient ventilation.
Properly configuring these settings optimizes energy savings while maintaining indoor air quality. Dampers modulate based on these parameters, maximizing free cooling when conditions are favorable. Careful consideration of building needs and climate is essential for effective control.
Troubleshooting Common Issues
Honeywell economizer systems can experience control failures, often linked to sensor malfunctions or damper problems. Diagnosing issues starts with verifying sensor readings – mixed air and outdoor air temperatures. Incorrect readings can trigger improper damper operation.
Damper control issues may stem from wiring problems or actuator failures. Regularly inspecting wiring connections and actuator functionality is crucial. Addressing these promptly ensures optimal system performance and energy efficiency.
Diagnosing Economizer Control Failures
Honeywell economizer control failures often manifest as inconsistent temperature regulation or unexpected system behavior. Begin by checking the JADE Advanced setup for error codes, providing initial clues. Verify power supply to the W7220 module and associated logic modules (W7212A, W7213A, W7214A).
Inspect wiring connections for looseness or corrosion. Confirm proper communication between the controller (like T775) and the economizer module. A systematic approach, utilizing available diagnostics, is key to pinpointing the root cause.
Addressing Sensor Malfunctions
Honeywell economizer systems rely on accurate sensor data; malfunctions require immediate attention. Begin by verifying the wiring to mixed air and outdoor air temperature sensors (MAT/OAT). Use a multimeter to check sensor resistance, comparing readings to specifications.
If a sensor fails testing, replace it with a compatible Honeywell part. Recalibrate sensors after replacement using the JADE Advanced setup. Ensure proper sensor placement, avoiding direct sunlight or airflow obstructions, for reliable performance.
Resolving Damper Control Problems

Honeywell economizer damper issues often stem from actuator failures or wiring faults. Inspect actuator connections and power supply, verifying correct voltage. Confirm the logic module (W7212A, W7213A, W7214A) is sending appropriate signals.
Manually check damper movement for obstructions. If the actuator is faulty, replace it with a Honeywell Series 72 compatible model. Recalibrate the system after actuator replacement, ensuring smooth and accurate damper positioning for optimal free cooling.

Maintenance and Best Practices
Honeywell economizer systems require regular inspection for optimal performance. Annually clean temperature sensors (MAT/OAT) and verify wiring connections. Calibrate sensors using a trusted reference, ensuring accurate readings for effective control.
Check damper operation and linkages for smooth movement. Regularly update JADE software and firmware to benefit from the latest features and bug fixes. Document all maintenance activities and maintain a log of sensor calibration dates for future reference.
Regular Inspection and Cleaning Procedures
Honeywell recommends inspecting economizer systems quarterly. Visually check for dust accumulation on mixed air and outdoor air temperature sensors, cleaning gently with compressed air. Inspect damper blades and linkages for obstructions or wear, ensuring free movement.
Verify wiring connections are secure and free from corrosion. Examine the controller enclosure for any signs of damage or moisture ingress. Document inspection findings and address any issues promptly to maintain optimal system efficiency and reliability.
Calibration of Temperature Sensors
Honeywell advises annual calibration of mixed air and outdoor air temperature sensors for accurate economizer control. Use a calibrated reference thermometer to compare readings. If discrepancies exceed the manufacturer’s specifications, adjust the sensor using the JADE Advanced Setup software.
Proper calibration ensures the economizer operates efficiently, maximizing free cooling potential. Document calibration dates and adjustments. Incorrectly calibrated sensors can lead to wasted energy and inaccurate temperature control, impacting building comfort.
Software Updates and Firmware Management
Honeywell regularly releases software and firmware updates for its economizer controllers, enhancing performance and addressing potential issues. Utilize the JADE Advanced Setup to check for and install available updates. Back up existing configurations before any update to prevent data loss.
Firmware updates often include new features, improved algorithms, and security enhancements. Consistent updates ensure optimal system operation and compatibility. Refer to Honeywell’s website for the latest versions and detailed installation instructions.
Safety Precautions
Honeywell economizer controller installations require strict adherence to electrical safety guidelines. Always disconnect power before working with wiring or components. Handle components with care, avoiding physical damage. Proper disposal of old parts is crucial, following local regulations.
In emergency situations, understand and utilize emergency shutdown procedures. Qualified personnel should perform all installations and maintenance. Never bypass safety features or attempt unauthorized modifications. Review all documentation before commencing work to ensure a safe installation.
Electrical Safety Guidelines
Honeywell economizer installations demand strict electrical safety. Always disconnect power at the breaker before accessing wiring. Utilize properly insulated tools and wear appropriate personal protective equipment. Verify voltage compatibility before connecting any components. Ensure all wiring connections are secure and meet local electrical codes.
Never work with live circuits. Grounding is essential for preventing electrical shock. Regularly inspect wiring for damage or wear. If unsure about any electrical aspect, consult a qualified electrician. Follow all manufacturer’s instructions regarding electrical connections.

Handling and Disposal of Components
Honeywell economizer components require careful handling. Avoid dropping or subjecting modules to physical shock. Store parts in a clean, dry environment, protected from extreme temperatures. When replacing components, maintain proper electrostatic discharge (ESD) precautions.
Dispose of old or faulty components responsibly, following local environmental regulations. Electronic waste should not be discarded with general trash. Contact a certified e-waste recycling facility for proper disposal methods. Refer to the Safety Data Sheets (SDS) for specific component handling guidelines.
Emergency Shutdown Procedures
Honeywell systems require swift action in emergencies. Immediately disconnect power to the economizer controller and associated HVAC equipment at the main breaker. This halts operation and minimizes potential hazards.
Isolate the system by closing relevant dampers and valves, if safely accessible. Notify qualified personnel for assessment and repair. Document the incident, including the time, conditions, and actions taken. Prioritize safety and avoid attempting repairs without proper training and authorization. Follow established facility emergency protocols.